13.12.2. Condenser


Prevention
Investigate connections of the condenser, without making considerable efforts, tighten them without exceeding the set moment. At assembly replace sealing rings.

Removal and installation
CARS WITH L ENGINES 2,6 AND 3,0 (12-VALVATE)

PERFORMANCE ORDER
1. Depressurize the highway of coolant in car service.

One-stage conditioner
2. Remove a forward lattice.
3. Carefully turn off the union on the condenser. On V6 engines there are 3 connections on the right and 4 connections at the left. On the engine of 2,6 l disconnect the highway on the condenser and disconnect a moisture separator.
4. Turn off bolts and remove a moisture separator.
5. Remove the condenser fan.
6. Turn off a bolt and remove the condenser.
7. Installation is carried out upside-down.
8. The union tighten with the moment 24 N. of m.

The two-level conditioner (with 2 condensers in a cooling contour)
9. Remove a facing lattice of a front of the car.
10. Carefully turn off the union of tubes on condensers and from the opposite side, turn off bolts and remove a moisture separator.
11. Remove the condenser fan.
12. Turn off a bolt from the opposite side of a moisture separator and remove the condenser.
13. Disconnect the socket from the auxiliary fan, turn off bolts and remove the second condenser.
14. Installation is carried out upside-down.
15. Replace sealing rings of unions.
16. The union tighten with the moment 24 N. of m.

CARS WITH ENGINES OF 3,0 L (24-VALVATE) AND 3,5 L

PERFORMANCE ORDER
1. Depressurize the highway of coolant in car service.
2. Disconnect the battery from weight.
3. Remove a facing lattice of a front of the car.
4. Remove a cowl lock arm.
5. Turn off bolts of a cooler of transmission liquid.
6. Turn off bolts of the oil heater, remove an arm.
7. Turn off bolts of fastening of the condenser.
8. Disconnect a tube of high pressure on the condenser and a moisture separator.
9. Remove a moisture separator and an arm.
10. Remove the condenser fan.
11. Disconnect the top hose of high pressure on the condenser.
12. Remove the condenser and get consolidations.
13. Installation is carried out upside-down.
14. Replace sealing rings of unions.
15. The union tighten with the moment 24 N. of m.